Testing & Input Validation

Across my project I made sure each part of my development was thoroughly tested, making sure that each section functioned properly. Below are the test cases and results.

TESTING

Early Development

Test Case Expected Result Actual Result Pass/Fail
Test if micro:bit turns on micro:bit should turn on with a flashing orange light at the back micro:bit turns on with flashing light Pass
Test if code being uploaded to micro:bit is run If code is run a circle should be displayed on micro:bit screen Circle is displayed Pass
Sensors connect to micro:bit and read data A row of sensor values displayed in micro:bit website Values displayed Pass
Data sent over serial correctly Code ran in VSCode prints each line of data as it received Lines are printed out but are sometimes missing values or incorrectly formatted Fail (fixed in next test case)
Data received over serial is discarded if values are incorrect If a bad line is sent, code does not append it to .csv Bad lines are not appended to .csv Pass
Correct timestamp added to .csv line Timestamp added with exact second Timestamp added with exact second Pass
Plotting software displays each sensor value graphed against time Air humidity, soil moisture, temperature, light intensity and flame graphed against time Graph is created with correct values Pass

Later Development

Test Case Expected Result Actual Result Pass/Fail
Test if mean and standard deviation of each value is found for simulation Mean and standard deviation printed to console All values print the mean and standard deviation Pass
Test if fire risk exceeds 50% that the pump and warning light turned on Drying soil moisture sensor to increase fire risk should turn water pump on Pump turns on when risk exceeds 50% Pass
Test if Stats are displayed after simulation has run Trees Burned, trees not burned, percentage of trees burned output to console Stats outputted Pass

CSV Input Validation

Input Result
0,23,46,78,97 Accepted
0,3,67,2 Rejected as only 4 values are present
1,56,,45,79,,,86 Rejected as extra commas are present
156,4579,86 Rejected as there is only 3 values

Serial Data Issues

Ran into a problem where my code was receiving bad data over serial from the micro:bit.

.csv lines were missing values, had extra commas, or too few commas. This in turn would break my modelling script as it returned an out-of-range error when fetching the values.

How I investigated and rectified these problems

I looked online for anyone with a similar issue: Forum post

I found a forum post explaining that having the Makecode website open while my Python code was running was causing garbled values to be sent.

Evidence showing how I fixed the problem

I fixed this problem by closing the Makecode website when my code was running. I also implemented a failsafe if bad values were sent. The addition to my code is shown here, highlighted in red

  while True:
    

try:

line = ser.readline().decode(errors="ignore").strip() timestamp = datetime.now() # wildfire_risk_with_timestamp.py #Read CSV and store values parts = line.split(",") light = (int(parts[0])) temp = (int(parts[1])) soil =(int(parts[2])) air =(int(parts[3])) ("Adding New line of Values") with open("artefact/log.csv", "a") as file: file.write(f"{timestamp},{line}\n") def wildfire_risk(): risk = (light/200 + temp/100+ (1-(soil/100)) + (1 - (air/100))) / 4 return risk #Print results with timestamp prob = wildfire_risk() ser.write((str(prob) + "\n").encode()) #from my brain print(f"{timestamp} → Wildfire Risk: {round(prob * 100)}%")

except Exception as e: print("Bad line of data sent") time.sleep(10) continue

Embedded System Algorithm

Model Equation

The algorithm I used to evaluate fire risk is

                
                risk =  (light/200) + 
                        (temp/100)+
                        (1-(soil/100)) + 
                        (1 - (air/100)) / 4
.

Each value in my equation is read from the sensors. Temperature is generally read between 0 and 100 in the forest, so I divide it by 100 to ensure it is no bigger than 1.


To show this algorithm working, I will sample a line of data from my log.csv file


           Timestamp, Light, Temperature, Soil Moisture, Air Humidity, Flame
           2026-03-18 09:35:56.238918,93,25,77,16,0 

Inputting these values gives

  
                risk =  (93/200) + 
                        (25/100)+
                        (1-(77/100)) + 
                        (1 - (16/100)) / 4
Solving this equation gives 0.446 or a 44.6% risk of fire

Higher soil moisture and air humidity values mean less chance of fire, which is why it is (1-soil_moisture) and (1-air_humidity). All values are divided by the max value that can be detected and then further divided by 4. This ensures the output risk of fire is a decimal between 0 and 1. This number is then multiplied by 100 to get the percentage value. You may notice that light is divided by 200, this is because the sensor had a tendency to read numbers almost exclusively in the 90's reacting very little to tests such as shining a torch on it, increasing only by 1 or 2 points

Limitations

A limitation I overlooked in development was the possibility of negative temperature values. This could lead to a negative fire risk being returned, which would not break the code but logically does not make sense.